All published articles of this journal are available on ScienceDirect.

RESEARCH ARTICLE

Effect of LED and Argon Laser on Degree of Conversion and Temperature Rise of Hybrid and Low Shrinkage Composite Resins

The Open Dentistry Journal 30 Sept 2016 RESEARCH ARTICLE DOI: 10.2174/1874210601610010538

Abstract

Objectives:

Different light curing units are used for polymerization of composite resins. The aim of this study was to evaluate the degree of conversion (DC) and temperature rise in hybrid and low shrinkage composite resins cured by LED and Argon Laser curing lights.

Materials and Methods:

DC was measured using FTIR spectroscopy. For measuring temperature rise, composite resin samples were placed in Teflon molds and cured from the top. The thermocouple under samples recorded the temperature rise. After initial radiation and specimens reaching the ambient temperature, reirradiation was done and temperature was recorded again. Both temperature rise and DC data submitted to one-way ANOVA and Tukey-HSD tests (5% significance).

Results:

The obtained results revealed that DC was not significantly different between the understudy composite resins or curing units. Low shrinkage composite resin showed a significantly higher temperature rise than hybrid composite resin. Argon laser caused the lowest temperature rise among the curing units.

Conclusion:

Energy density of light curing units was correlated with the DC. Type of composite resin and light curing unit had a significant effect on temperature rise due to polymerization and curing unit, respectively.

Keywords: Argon laser, DC, LED, Low shrinkage composite, Temperature rise.
Fulltext HTML PDF ePub
1800
1801
1802
1803
1804