In Vitro Assessment of Apical Leakage of Bioceramic Endodontic Sealer with Two Obturation Techniques

All published articles of this journal are available on ScienceDirect.

RESEARCH ARTICLE

In Vitro Assessment of Apical Leakage of Bioceramic Endodontic Sealer with Two Obturation Techniques

The Open Dentistry Journal 31 Dec 2018 RESEARCH ARTICLE DOI: 10.2174/1874210601812011162

Abstract

Purpose:

The aim of this study was to evaluate the apical sealing ability of Total Fill BC sealer and AH Plus sealer with single cone and continuous wave condensation obturation techniques using dye extraction leakage method.

Materials and Methods:

Eighty-four extracted human single-rooted teeth with round canals were decoronated at 12 mm length and instrumented using crown down technique with the iRace rotary file system to apical file size 40 with 0.04 taper. The roots were randomly divided into four experimental groups (n=20). Group (A1) contained roots which were obturated with Total Fill BC sealer with a single cone. Group (A2) contained roots which were obturated using Total Fill BC sealer with continuous wave condensation. Group (B1) contained roots which were obturated using epoxy resin sealer (AH Plus) with a single cone. Group (B2) contained roots which were obturated using AH Plus sealer with continuous wave condensation.

Apical microleakage was assessed with dye extraction method where the absorbance of leaked 1% methylene blue dye was measured using a spectrophotometer. The absorbance values were converted into concentrations, and the data was analyzed using One way ANOVA test.

Results:

The mean dye concentration values were 0.012, 0.016, 0.011 and 0.015 for Group A1, Group A2, Group B1 and Group B2, respectively.

One-way ANOVA indicated no significant difference in dye leakage between the investigated groups (F = 0.938).

Conclusion:

With the limitation of the study, it was concluded that Total Fill BC was equivalent to AH Plus in apical sealing ability when using single cone or continuous wave condensation. The single cone can provide a similar apical seal of canal filling as can be achieved by using continuous wave condensation methods, in the round canal.

Keywords: AH plus, Dye extraction, Sealing ability, Single cone, Total fill BC, Endodontic Sealer.

1. INTRODUCTION

The ultimate goal of root canal system obturation is to provide a hermetic seal to prevent the leakage of fluid and antigenic agents into or from the peri-radicular tissue [1]. The essential components of a root filling are: a solid core material and a sealer. The widely used core material is gutta-percha, which occupies the bulk of the canal space while the root canal sealer fills the interface between the core material and dentine wall [2].

A variety of endodontic sealers are available commercially and they are divided into different groups according to their chemical composition such as zinc oxide eugenol, glass ionomer, calcium hydroxide, silicon and resin. Several studies have been carried out to compare the sealing property of various sealers, but there is hardly any common consensus [3, 4]. Some studies showed that the resin-based sealer provided a better seal than other sealers [5-8].

Recently, bioceramic based sealers have been introduced in endodontics. They are compatible, antibacterial and bind to dentinal tubules, which improve the sealing ability and prevent the microleakage [9]. Total Fill BC sealer is a new calcium silicate based sealer that has not much investigated in terms of its capability to serve as the apical seal.

Apical leakage is considered the common cause for endodontic failure and is influenced by many variables such as different filling techniques, chemical and physical properties of root canal filling materials and presence and absence of smear layer [10, 11].

Several methods to evaluate leakage have been used in endodontic including dye penetration, bacterial penetration, and fluid filtration methods [12-14]. The dye extraction technique has long been used in endodontic because it gives a quantitative result, it is easy, does not require sophisticated materials and takes into account all absorbed dye in the samples [15].

The purpose of this investigation is to evaluate the apical sealing ability of Total fill BC sealer and AH Plus sealer using a single cone and continuous wave compaction obturation techniques with dye extraction method.

2. MATERIALS AND METHODS

2.1. Sample Selection and Preparation

Eighty-four human permanent single-rooted teeth were collected and used in the study. All teeth were cleaned of extraneous tissue and calculus by using an ultrasonic scaler and exposed to digital radiograph from facial and proximal side to ensure the presence of a single root canal with the fully developed apex. Under stereomicroscope with x35 magnification, each tooth was examined to confirm one apical canal opening, absence of apical cracks and root fracture.

Each tooth was radiographed in Buccolingual (BL) and Mesiodistal (MD) projections to evaluate the shape of the root canal and check if there is any of the exclusion criteria. The canal measured at 5mm from the apex. The cross-section morphology of the root canal is classified as round when the radiographic measurement of MD and BL or Diameter Ratio (DR) is similar.

The coronal portion of all teeth was removed using a Precision Saw under the cement-enamel junction to standardize the root length of 12 mm from the anatomic apex measured by digital caliper. The working length was determined by subtracting 1mm from the total length of the root by using 10-K file.

2.2. Root Canal Preparation

Biomechanical preparation of the canals was performed by using a crown-down technique with the iRace rotary file system (FKG, Switzerland) starting with R1, R2, R3, #35 and #40 with 0.04 taper. Each canal was irrigated after each rotary file with 1 ml 5.25% NaOCL using a disposable side vented needle with 30 G and ensuring patency by extrusion of the solution beyond the apical foramen. Finally, the root canal was irrigated with 3 ml of 17% EDTA solution for one minute (Meta Biomed, Korea) followed by 3 ml of 5.25% sodium hypochlorite for one minute, and then flushed with 5 ml of distilled water.

All the canals were dried with paper point size 40 with 0.04 taper until dry paper point come out. After completing the biomechanical preparation, the roots were coated with two layers of nail varnish and to prevent covering the apical foramen with nail varnish, a size 10-K file was placed passing through it. Each coat was left to dry before the next layer was applied to the surface of the root.

2.3. Grouping and Obturation

The prepared roots were divided randomly based on the sealer material used and obturation techniques into four experimental groups of 20 roots, and two control group of two roots each:

Group A1: Total Fill BC sealer (FKG, Switzerland) was used with single cone obturation technique.

Group A2: Total Fill BC sealer was used with continuous wave condensation technique (Elements system, Kerr, USA).

Group B1: AH Plus sealer (Dentsply, Germany) has been used with single cone obturation technique.

Group B2: AH Plus sealer was used with continuous wave condensation technique.

Positive control: Two samples were used in which the canals were not obturated. The roots were coated with two layers of nail varnish except the apical opening.

Negative control: Two samples were obturated by using single cone gutta-percha size 40 with 0.04 taper with AH Plus sealer, and they were sealed apically with two layers of nail varnish to prevent the dye penetration.

2.4. Dye Application and Extraction

A 2 ml of 1% concentration methylene blue dye was injected into a glass vial to assess the apical seal. Each root was sealed using silicon glue into the vial, and then each vial was inverted in which the apical foramen pointing upward to be sure that apical part covered completely with the dye and the gravity will enhance dye penetration stored in a dark cabinet at room temperature for a period of seven days. Then they were taken out and washed thoroughly with running tap water until the clear water was seen in the container. Samples were dried, and nail varnish was removed by scratching it with a scalpel blade. The teeth were then placed in a glass test tube filled with 4.0 ml of 65% nitric acid solution for 72 hr. The solutions were centrifuged for 7 minutes at 4000 rpm (EBA, USA) and the supernatant was subjected to absorbance measurements.

2.5. Measurement of Leaked Dye Concentrations

The absorbance of leaked dye, in nm, from each sample, was measured by using UV mini 1240 spectrophotometer device (Shimadzu, Japan) with photometric mode and 600 nm lambda in a standardized volume of 3.0 ml of a solution of each sample.

The absorbance of each sample of all groups was measured three times using the same zircon cuvette (Beckman, California, USA). The same operator measured all samples on the same day under the same conditions.

Standard solutions of 1%, 0.5%, 0.1%, 0.05% and 0.01% of methylene blue in 65% nitric acid were prepared and stored for 72 hours in dark cabinet at room temperature.

The absorbance was converted to concentration (µg/ml) using Beers law as follows:

Cu / Cs = Au / As Cu = Cs (Au /As)

Where

Cs: The prepared Known concentration of methylene blue dye.

As: The absorbance of the prepared known concentration of methylene blue dye measured by spectrophotometer.

Au: The absorbance of the unknown sample determined by spectrophotometer.

Cu: Concentration of the unknown sample.

All the samples absorption were applied to the equation to discover the amount of methylene blue dye concentration in it.

2.6. Statistical Analysis

Data were collected and submitted to statistical analysis using a software program (IBM SPSS statistics, version 22, Chicago, IL, USA). The data were analyzed using One-way analysis of variance (ANOVA). A P-value of < 0.05 was considered statistically significant.

3. RESULTS

All the experimental groups showed an apical leakage (Fig. 1). The means and standard deviations of dye concentration were as follows: Total Fill BC with a single cone (0.012 ± 0.012), Total Fill BC with continuous wave condensation (0.016 ± 0.013), AH plus with a single cone (0.011 ± 0.011), AH plus with continuous wave condensation (0.015 ± 0.009).

Fig. (1). Bar chart shows dye concentration µg/ml for all study groups.

The result of this study showed there was no significant difference found between the four groups using the One way ANOVA test (F = 0.938) (Table 1).

Table 1.
One- way ANOVA statistics of the dye concentrations (µg/ml) in study groups.
Concentration Sum of Squares df Mean Square F Sig.
(P value)
Between Groups .000 3 .000 .938 .427
Within Groups .010 76 .000
Total .010 79

4. DISCUSSION

A variety of sealers have been used in endodontics. Total Fill BC sealer is recently presented. The bioceramic endodontic sealer consists of calcium silicate and calcium phosphate groups. The manufacturer stated that the sealer is biocompatible and nontoxic.

Total Fill BC sealer has the same composition of Endosequence BC sealer and has both excellent physical properties and biocompatibility. Superior qualities and handling abilities make Total Fill BC sealer as an innovative novel root canal sealer that does not shrink during setting and hardens in the presence of moisture [16]. The small particle size, hydrophilicity and low contact angle of this cement allow it to spread easily over the dentinal walls of the canal and get inside and fill the lateral microcanals. It also exhibits a significant expansion of 0.20%. These features create a gap-free chemical bond between the sealer and dentinal walls [17].

The setting reaction of Total Fill BC sealer initiated by moisture and the final set was achieved approximately two hours later with the calcium silicate portion of the material producing a calcium silicate hydrate gel and calcium hydroxide. The calcium hydroxide then interacted with phosphate ions from dentine to form hydroxyapatite and water. The water produced continued to react with the calcium silicate to precipitate additional gel-like calcium silicate hydrate [18].

The result of the present study showed that there were no significant differences between the four experimental groups when evaluated by dye extraction method using One Way ANOVA statistical analysis (P > 0.05).

Zang et al. in 2009 [16] concluded in their research that there were no significant differences in the apical leakage between iRoot and AH Plus using single cone and continuous wave condensation techniques. iRoot is a calcium silicate bioceramic sealer that has almost the same composition of Total Fill BC Sealer. Bayram et al. 2017 [19], compared the push-out strength of AH Plus, MTA Fillapex and Total Fill BC sealer in mandibular premolars. The AH Plus and Total Fill BC sealer showed similar strength in bonds to the root canal wall. A study done by Sagsen et al. 2011 [20], assessed the push out bond strength of two calcium silicate based endodontic sealers MTA and iRoot SP and compared them with AH Plus sealer in root canals of extracted teeth, and found that in the coronal specimen, there was no significant difference between the sealers.

Although there were no significant differences between the two groups (A1 and B1) in the outcome of this study, the single cone with Total Fill BC showed more apical leakage than single cone with AH Plus sealer. Similar results were concluded in a study conducted by Polineni et al. 2016 [21] when they assessed the marginal adaptation of epoxy resin based sealer Micro Megaseal sealer (Epoxy resin sealer), MTA Fillapex and Endosequence BC sealer to dentine with single cone obturation technique using the scanning electron microscopy. The epoxy resin sealer showed better marginal adaptation than BC sealer and MTA fillapex. The variation in dentin surface energy because of using EDTA solution can significantly reduce its wetting ability and thus reduce the adhesion of hydrophilic root canal sealer [22].

The superior adaptation of the epoxy resin sealer could be due to its ability to bond to root dentine chemically by reacting with any exposed amino groups in collagen to form a covalent bond between the resin and collagen upon opening of epoxide ring [23]. Unlike alkaline bioceramic based sealers, AH Plus sealer is slightly acidic and might result in self-etching when in contact with dentine, thereby enhancing interfacial bonding and adaptation [24].

In the current study, the use of calcium silicate sealer with single cone obturation technique resulted in less leakage compared to continuous wave condensation technique. DeLong et al. 2015 [25], evaluated the effect of obturation technique on the push-out bond strength of calcium silicate sealers. They concluded that bioceramic and MTA Plus sealers showed favorable bond strengths when used with single cone obturation technique. The continuous wave obturation technique decreases the bond strength of the bioceramic sealers. They stated that it is possible that the system B heat source mechanically removes the sealer during the down-pack, thus reducing or eliminating it from the canal. Viapiana et al. [26] in their study found minimal chemical changes in bioceramic sealer (MTA Plus) when subjected to warm vertical compaction.

Hegde and Arora [27] showed that the Endosequnce BC sealer provides superior sealing ability with the single cone obturation technique. McMichael et al. [28] obtained similar outcomes in this study in which they examined the dentinal tubules penetration of tricalcium silicate sealers using continuous wave condensation and single cone obturation techniques. They concluded that the continuous wave condensation and single cone obturation techniques produced similar tubule penetration at both 1mm and the 5mm level with the tricalcium silicate sealers.

A recent study by Kim et al. [29] evaluated the root filling quality of calcium silicate based sealer with both single cone and continuous wave condensation obturation techniques by measuring the percentage of voids. They concluded that the percentage of voids inside the filling materials was significantly higher in the continuous wave condensation obturation groups, except in the apical area of the distal canal. The voids between the filling material and canal wall in the apical area were not significantly different between the two techniques.

CONCLUSION

With the limitation of the study, it can be concluded that:

  1. No types of sealers and obturation techniques used in the current study prevented apical microleakage.
  2. There were no significant differences in apical microleakage between the Total Fill BC sealer and AH plus sealer when used in two different obturation techniques (single cone and continuous wave of compaction technique) using the dye extraction method.
  3. The single cone can provide a similar apical seal of canal filling as can be achieved by using continuous wave condensation methods, in the round canal.

ETHICS APPROVAL AND CONSENT TO PARTICIPATE

Ethical approval to conduct the study was obtained from the Research Ethics Committee at Ajman University (RD- 2016/ 17-10).

HUMAN AND ANIMAL RIGHTS

No animals were used in this research. All human research procedures followed were in accordance with the ethical standards of the committee responsible for human experimentation (institutional and national), and with the Helsinki Declaration of 1975, as revised in 2013.

CONSENT FOR PUBLICATION

Following review by the Research Ethics Committee, College of Dentistry, Ajman University of Science and Technology, permission is granted for this study to proceed as given in the proposal taking in consideration that a waiver of consent has been permitted.

CONFLICT OF INTEREST

The authors declare no conflict of interest, financial or otherwise.

ACKNOWLEDGEMENTS

Declared none.

REFERENCES

1
Sundqvist G, Figdor D, Persson S, Sjögren U. Microbiologic analysis of teeth with failed endodontic treatment and the outcome of conservative re-treatment. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1998; 85(1): 86-93.
2
Salz U, Poppe D, Sbicego S, Roulet JF. Sealing properties of a new root canal sealer. Int Endod J 2009; 42(12): 1084-9.
3
Chailertvanitkul P, Saunders WP, Mackenzie D. An assessment of microbial coronal leakage in teeth root filled with gutta-percha and three different sealers. Int Endod J 1996; 29(6): 387-92.
4
Miletić I, Anić I, Pezelj-Ribarić S, Jukić S. Leakage of five root canal sealers. Int Endod J 1999; 32(5): 415-8.
5
Monticelli F, Sadek FT, Schuster GS, et al. Efficacy of two contemporary single-cone filling techniques in preventing bacterial leakage. J Endod 2007; 33(3): 310-3.
6
McMichen FR, Pearson G, Rahbaran S, Gulabivala K. A comparative study of selected physical properties of five root-canal sealers. Int Endod J 2003; 36(9): 629-35.
7
Timpawat S, Amornchat C, Trisuwan WR. Bacterial coronal leakage after obturation with three root canal sealers. J Endod 2001; 27(1): 36-9.
8
Economides N, Liolios E, Kolokuris I, Beltes P. Long-term evaluation of the influence of smear layer removal on the sealing ability of different sealers. J Endod 1999; 25(2): 123-5.
9
Vitti RP, Prati C, Silva EJ, et al. Physical properties of MTA Fillapex sealer. J Endod 2013; 39(7): 915-8.
10
Pommel L, Jacquot B, Camps J. Lack of correlation among three methods for evaluation of apical leakage. J Endod 2001; 27(5): 347-50.
11
Valois C, de Castro A. Comparison of the apical sealing ability of four root canal sealers. J Bras Endo 2002; 3: 317-22.
12
Veríssimo DM, do Vale MS. Methodologies for assessment of apical and coronal leakage of endodontic filling materials: A critical review. J Oral Sci 2006; 48(3): 93-8.
13
Torabinejad M, Ung B, Kettering JD. In vitro bacterial penetration of coronally unsealed endodontically treated teeth. J Endod 1990; 16(12): 566-9.
14
Vasconcelos BC, Bernardes RA, Duarte MA, Bramante CM, Moraes IG. Apical sealing of root canal fillings performed with five different endodontic sealers: Analysis by fluid filtration. J Appl Oral Sci 2011; 19(4): 324-8.
15
Bargholz C. Perforation repair with mineral trioxide aggregate: A modified matrix concept. Int Endod J 2005; 38(1): 59-69.
16
Zang W, Li Z, Peng B. Assessment of new root canal sealers apical sealing ability. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 107(6): 79-82.
17
Kossev D, Stefanov V. Ceramics-based sealers as new alternative to currently used endodontic sealers. Res Ceramics-based Seal 2009; 1: 42-8.
18
Ma J, Shen Y, Stojicic S, Haapasalo M. Biocompatibility of two novel root repair materials. J Endod 2011; 37(6): 793-8.
19
Bayram H, Brayam E, Kanber M, Celikten B, Saklar F. Effect of different chelating solutions on the push- out bond strength of various root canal sealers. Biomed Res 2017; (Special issue): S401-6.
20
Sagsen B, Ustün Y, Demirbuga S, Pala K. Push-out bond strength of two new calcium silicate-based endodontic sealers to root canal dentine. Int Endod J 2011; 44(12): 1088-91.
21
Polineni S, Bolla N, Mandava P, Vemuri S, Mallela M, Gandham VM. Marginal adaptation of newer root canal sealers to dentin: A SEM study. J Conserv Dent 2016; 19(4): 360-3.
22
Al-Zaka I, Ammar A, Hikmet A, Mehdi J. The effect of different root canal irrigants on the sealing ability of bioceramic sealer. MDJ 2013; 1: 1-7.
23
Gade VJ, Belsare LD, Patil S, Bhede R, Gade JR. Evaluation of push-out bond strength of endosequence BC sealer with lateral condensation and thermoplasticized technique: An in vitro study. J Conserv Dent 2015; 18(2): 124-7.
24
Al-Haddad A, Abu Kasim NH, Che Ab Aziz ZA. Interfacial adaptation and thickness of bioceramic-based root canal sealers. Dent Mater J 2015; 34(4): 516-21.
25
DeLong C, He J, Woodmansey KF. The effect of obturation technique on the push-out bond strength of calcium silicate sealers. J Endod 2015; 41(3): 385-8.
26
Viapiana R, Baluci CA, Tanomaru-Filho M, Camilleri J. Investigation of chemical changes in sealers during application of the warm vertical compaction technique. Int Endod J 2015; 48(1): 16-27.
27
Hegde V, Arora S. Sealing ability of three hydrophilic single-cone obturation systems: An in vitro glucose leakage study. Contemp Clin Dent 2015; 6(Suppl. 1): S86-9.
28
McMichael GE, Primus CM, Opperman LA. Dentinal tubule penetration of tricalcium silicate sealers. J Endod 2016; 42(4): 632-6.
29
Kim S, Kim S, Park JW, Jung IY, Shin SJ. Comparison of the percentage of voids in the canal filling of a calcium silicate-based sealer and gutta-percha cones using two obturation tehniques. Materials (Basel) 2017; 10(10): 1170.